◆ sx_err2str()

const char * sx_err2str ( int sx_err)
inline

#include <subsys/nrf_security/src/drivers/cracen/common/include/cracen/sx_error.h>

Function to convert CRACEN SW library error codes to strings for logging.

Parameters
[in]sx_errError code from sxsymcrypt or silexpk.
Returns
String literal representing the error code.

Waiting on the hardware to process this operation

No compatible hardware for this operation.

This error occurs if the dedicated hardware to execute the operation is not present, or hardware is present and operation not supported by it.

Hardware DMA error

Fatal error that should never happen. Can be caused by invalid or wrong addresses, RAM corruption, a hardware or software bug or system corruption.

Fatal error, trying to call a function with an uninitialized object

For example calling sx_aead_decrypt() with an sxaead object which has not been created yet with sx_aead_create_*() function.

Fatal error, trying to call an AEAD or block cipher create function with an uninitialized or invalid key reference.

Examples: calling sx_blkcipher_create_aesecb() with a key reference which has not been initialized yet with sx_keyref_load_material() or sx_keyref_load_by_id() function, sx_keyref_load_material() was called with key NULL or size 0, or sx_keyref_load_by_id() was called with an invalid index ID.

Hardware cannot work anymore.

To recover, reset the hardware or call *_init() function. For example, if this error is received when sx_trng_get() is called, call again sx_trng_open() to reset the hardware.

The signature is not valid

This error can happen during signature generation and signature verification

The modulus has an unexpected value

This error happens when the modulus is zero or even when odd modulus is expected

The input operand is too large

Happens when an operand is bigger than one of the following:

  • The hardware operand size: Check ::sx_pk_capabilities to see the hardware operand size limit.
  • The operation size: Check sx_pk_get_opsize() to get the operation size limit.

The hardware is still in IK mode

This error happens when a normal operation is started and the hardware is still in IK mode. Run command ::SX_PK_CMD_IK_EXIT to exit the IK mode and to run normal operations again

The IK module is not ready

This error happens when a IK operation is started but the IK module has not yet generated the internal keys. Call sx_pk_ik_derive_keys() before starting IK operations.

The size passed as part of a request is not valid

A PRNG reseed is required

An invalid parameter was passed to a function

The task is ready for consume, produce, run or partial run

Hash algorithm not supported

The ciphertext is not valid

The number of attempts in an algorithm has exceeded a given threshold

Range checks, performed on p and/or q during RSA key generation, failed

Function needs bigger workmem buffer than what is provided *