nrfxlib API 3.3.99
|
| void nrf_802154_trx_ppi_for_fem_set | ( | void | ) |
Configure PPIs needed for external LNA or PA. Radio DISABLED event will be connected to timer START task. As a result, FEM ramp-up will be scheduled during the radio ramp-up period, with timing based on FEM implementation used.