Debugging nRF93M1
This page describes how to collect modem traces and modem coredumps from the nRF93M1 module, for your own debugging or for Nordic technical support. For metrics that nRF Cloud collects continuously, see Firmware observability.
Modem trace
The module produces a real-time binary modem trace that shows the AT commands, IP packets, and the LTE RRC and NAS-EPS signaling exchanged with the network. Capture a trace when you debug registration, connectivity, or power saving problems, and when Nordic technical support asks for one.
The trace is not buffered or stored in the module, so you must capture it while the problem occurs.
You can send the trace to UART0, to the USB interface of the nRF93M1, or to both.
The default is both.
On the nRF93M1 DK, use the USB interface of the nRF93M1 (vcom1), which is available on the connector labeled USB2.
Requirements
Capturing a trace requires the following:
The
tracecommand of nRF Util. See Installing and upgrading nRF Util commands.The Wireshark application with the nRF Util plugins. See nRF Util Wireshark plugins.
Trace output enabled on the module. Trace output is enabled by default.
The power saving configuration in Optimizing power consumption disables the trace output with
AT%MODULECFG="logCtrl",0and the USB interface withAT%MODULECFG="usbCtrl",2. If you used it, enable both again over UART1, and reset the module before you capture:AT%MODULECFG="logCtrl",2 OK AT%MODULECFG="usbCtrl",0 OK
Capturing a trace
Connect USB2 on the DK to your computer and find the trace port:
The nRF93M1 is listed with three virtual COM ports. Note the port with
vcom: 1. In the following example, the trace port is/dev/ttyACM3:2623CKLQ0001610 Product nRF93M1 Ports /dev/ttyACM2, vcom: 0 /dev/ttyACM3, vcom: 1 /dev/ttyACM4, vcom: 2 Traits nordicUsb, serialPorts, usb
Start the capture, and save the raw trace data and a PcapNG file:
Windows
nrfutil trace lte --input-serialport COM1 --output-raw trace.bin --output-pcapng <file_name>
Linux, macOS
nrfutil trace lte --input-serialport /dev/ttyACM3 --output-raw trace.bin --output-pcapng <file_name>
Use the port from the previous step as the serial port.
Reproduce the problem. For example, send the AT commands over the AT port while the capture runs:
AT+CFUN=0 OK AT+CFUN=1 OK
Press Ctrl+C to stop the capture. Stop it this way so that the output files are finalized.
Viewing a trace
Open the trace.pcapng file in Wireshark.
To view the trace live, see Viewing modem traces in Wireshark.
To convert the trace.bin file later, see Converting modem trace data.
Note
If nRF Util cannot select the trace database for the modem firmware, give the version with --mfw-revision-id, for example --mfw-revision-id mfw_nrf93m1_1.5.0.
Read the version with AT+CGMR.
The following table lists the %MODULECFG parameters that configure the trace:
Parameter |
Values |
|---|---|
|
Output interface: |
|
Logging: |
|
Log print level, from |
All three settings take effect after a reset. UART0 requires a baud rate of at least 921,600 bps and supports up to 6 Mbps. Make sure that your capture hardware can handle the data rate.
Modem coredumps
If the modem firmware crashes or hits an assertion, the module collects information about the state at the time of the crash in a coredump. Coredumps are always collected, but they are never exported or uploaded unless you enable it. You then decide when to send a coredump, for example when Nordic technical support asks for it.
A coredump has the following properties:
It is stored in the OTA partition of the module and stays there until you export, upload, or delete it, or until an OTA update overwrites it.
A new crash does not overwrite an existing coredump.
It is encrypted, so you cannot read it yourself. Nordic can decode it with the modem firmware symbols that match your firmware version.
When the module starts and finds a valid coredump, it prints the following unsolicited result code:
%NRFCLOUDOBS: coredump available (43 KB)
Enabling coredump reporting
By default, AT%NRFCLOUDOBSUPLOAD and AT%NRFCLOUDOBSEXPORT do not include coredumps.
To include them, enable coredump reporting:
AT%NRFCLOUDOBSCOREDUMP=1
OK
The setting is stored in the modem configuration, so it persists.
Read the current setting with AT%NRFCLOUDOBSCOREDUMP?.
Uploading a coredump to nRF Cloud
Use this method when the device is registered to the network and provisioned to nRF Cloud. See Provisioning a device.
Enable network registration status reports and go online:
AT+CEREG=1 OK AT+CFUN=1 OK +CEREG: 2 +CEREG: 5
Status
1or5means that the device is registered, and you can continue.Enable coredump reporting, and add a heartbeat so that the report contains additional information about the device:
AT%NRFCLOUDOBSCOREDUMP=1 OK AT%NRFCLOUDOBSHEARTBEAT OK
Upload the data to nRF Cloud:
AT%NRFCLOUDOBSUPLOAD %COAP: RESPONSE,2.01 %COAP: DATA,8,Accepted ... %NRFCLOUDOBSUPLOAD: UPLOADED,18 OK
The coredump is removed from the module automatically after it is uploaded.
nRF Cloud stores the coredump as a custom data recording (CDR) of the device, with the reason mfw_coredump.
To find it, open the page of the device in nRF Cloud and check the Timeline.
Download the file and provide it, together with a description of the situation in which the crash happened, to Nordic technical support.
Exporting a coredump over the serial port
Use this method when the device cannot connect to the cloud. Configure your serial terminal to capture the output before you start, because each exported line is very long.
Use the following commands to export a coredump:
AT%NRFCLOUDOBSCOREDUMP=1
OK
AT%NRFCLOUDOBSHEARTBEAT
OK
AT%NRFCLOUDOBSEXPORT
MC:wOVH2q6i7t5m3t(...)ztQ==:
MC:wOVH2q6i7t5m3t(...)ztQ==:
OK
The command prints the data as base64-encoded chunk lines that start with MC:.
The coredump is removed from the module automatically after it is exported.
Save the full output to a text file and provide it to Nordic technical support, together with a description of the situation in which the crash happened.
Capturing a RAM dump with nRF Util
When the modem crashes, the module can also send a full dump of its memory (a RAM dump) to nRF Util, in addition to storing the coredump.
The faultAction parameter of the %MODULECFG command selects what the module does when the modem firmware crashes:
Value |
Action |
|---|---|
|
Dump the exception information to flash and to the tool, then halt. |
|
Print the exception information, then reset. |
|
Dump the exception information to flash, then reset. |
|
Dump the exception information to flash and to the tool, then reset. |
|
Collect the observability chunks, then reset. This is the default. Export or upload the chunks as described in the previous sections. |
|
Dump the exception information to flash, the tool, and UART, then halt. |
|
Dump the exception information to flash, the tool, and UART, then reset. |
To capture a RAM dump, complete the following steps:
Select an action that dumps to the tool and resets the module afterwards. The setting is stored in the module configuration:
AT%MODULECFG="faultAction",3 OK
Start a trace capture on the trace port, as described in Modem trace, and give a directory for the dump with the
--x-output-ramdump-diroption:Reproduce the crash. When the modem crashes, the trace shows that the module enters the dump handshake mode. nRF Util then writes the RAM dump to the directory as a
ramdump_<date>_<time>.binfile of a few megabytes.Provide the RAM dump to Nordic technical support, together with a description of the situation in which the crash happened.
The module resets after the dump, and the USB ports are enumerated again, so the capture session ends.
Start a new capture if you want to continue tracing.
Set faultAction back to 4 when you have collected the dump, so that the module returns to the default behavior.
Deleting a coredump
To delete a stored coredump without exporting it, erase the OTA partition:
AT%FWUPD=0
OK
Updating the modem firmware over the air also overwrites a stored coredump.